Skip to main content
BKN-90

BKN-90

PVC Water Stop Bar

Advantages:

  • Easy to use, high effective.
  • High waterproof when concrete gets setting.
  • Bonding well with concrete.
  • Chemical and alkaline resistance.
  • There are many types to suit each location of structure
Download technical documents

BKN-90

Technical summary

Category

Waterproofing & Fillings

PVC Water Stop Bar

BKN-90 is made from plastic PVC, heat resistance, aging resistance. Product is designed to waterproof for expansion joints, settlement joint, construction joint, cold joint,….

Product data

PurposeType
Construction jointSV150 SV200 SV250 SV320
Expansion jointO150 O200 O250
Chemical basePolyvinyl Clorua
Appearance / ColorFlexible strip/ Yellow
Density1.40 ± 0.02 kg/liter @ 250C.
Shore A hardeness> 65 (ASTM 2240 -02)
Tensile strength≥ 11.8 MPa (Meet the requirements of TCVN 9407:2014 and JIS K6773:2007)
Extension: ​≥ 250% (Meet the requirements of TCVN 9407:2014 and JIS K6773:2007)
Application temperature-55oC÷55oC
Chemical resistanceAcid, alkaline resistance, waste water resistance, seawater resistance.
Connection temperature≥ 200oC
Storage ConditionStore in a dry, cool place, freeze-free area

Applications

  Construction joint:

  • Use BKN-90 V in the middle structure. Formwork positioning: the positioning method allows a half BKN-90 V projecting hose and the rest will be entombed in concrete. BKN-90 V will be positioned by formworks. Constructive reinforcement positioning: Use wire to link with steel bar of structure to position BKN-90 V not move during the concrete placement. BKN-90 V does not use to separate the mass concrete.

Expansion joint:

  • Use BKN-90 O in the middle structure. BKN-90 O can be positioned by formwork of 2 parts separated. However, when using BKN-90 O for expansion joint, and construction joint moving, the letter

Concrete placement:

Period 1:

  • Before pouring concrete must check the installation and location of joints,… BKN-90 will promote the features when both sides are deep on concrete, the concrete placement must comply with the technical requirement to avoid concrete being void at the joint location. Concrete aggregate with a grain size suitable aggregate, the slump is not too high or too low. During concrete placement must evenly distribute the pressure of 2 sides of BKN90 to avoid BKN-90 being folded back.

Period 2:  

  • Remove formwork carefully around BKN-90, and recheck concrete at the joint position is void or not, if yes, should be repaired. Clean the dropping concrete on BKN-90 of period 1. Then pouring concrete for the next.

Solder joint:

Use electric knife welding to weld in the construction site

  • Butt weld: Heated together both ends of the weld by electric knife welding until PVC layer flowing, take knife out and squeeze two joints together, hold until the joint welding is cool and stick together. Recheck if the joint welding does not meet, must reweld.
  • Lap welding: Heated together both ends of the weld about 5cm when PVC flowing, take knife out and squeeze two joints together until the lap welding is cool and stick together.

Cleaning:

  • Proper disposal in accordance with local

Safety:

  • Non-toxic. But be aware to avoid inhaling smoke and steam in the process of welding PVC. Therefore be clear position welding.

Advantages

  • Easy to use, high effective.
  • High waterproof when concrete gets setting.
  • Bonding well with concrete.
  • Chemical and alkaline resistance.
  • There are many types to suit each location of structure
BKN-90 is made from plastic PVC, heat resistance, aging resistance. Product is designed to waterproof for expansion joints, settlement joint, construction joint, cold joint,….