BestCoat EP606

Technical summary

Category

Floorings

Non-solvent Epoxy Coating, Two components

BestCoat EP606 is an epoxy coating, non solvent, two components, protective coating for industrial flooring surface or some surfaces required load bearing, abrasion resistance, chemical resistance.

Product data

ColorYellow, blue, green, brown, gray. (Color can be optional in accordance to the minimum required quantity)
DensityComponent A: 1.57 kg/liter @ 25oC; Component B: 0.98 kg/liter @ 25oC. Mixture A+B : 1.43 kg/liter @ 25oC.
Solid content100%
Consumption: ​0.10 ÷ 0.25 kg/m2 /layer (depend on surface condition
Application temperatureMinimum: 10oC (but above dew point temperature of 5oC) Maximum: 35 oC Relative humidity ≤ 80% ​
Chemical resistanceResistance to water, acid, alkali, seawater, grease, fuel and other common chemicals.
Thermal resistanceDry heat: Up to 120oC Damp heat: Up to 80oC
Mechanical strengthHigh strength and mechanical abrasion resistance.
Mixing ratioPart A : Part B = 5:1 (by weight)
PreserveIn cool, dry place
Shelf - life12 months from manufactured date
Packaging5kg/set; 25kg/set
Pencil hardness≥ 3H
Bonding strength≥ 1.5MPa (concrete failed)
Environment temperature+20oC
Pot-life (minutes)90
Environment temperature+20oC
Waiting time       Minimum24 Hrs
Maximum2 days
Walk-ability30 hours
Light loading capacity5 days
Complete curing10 days

Applications

Coating system:

  • To strongly absorb, the easily breakable, or hardened surface must be applied a primer layer by BestPrimer EP601, BestPrimer EP602, or BestPrimer EP603.
  • To smooth the surface, solid and medium roughness does NOT apply the primer layer but should apply at least 2 layers of BestCoat EP606 after cleaning the surface.

Substrate requirement:

  • To concrete surface: Compressive strength:  20 MPa, tensile strength:  1.5 MPa. The surface should be flat, solid, and dry (maximum moisture is 4%), and impurities, broken pieces, and dust should be removed. 
  • To metal surface: should be removed rust, oil or impurities…

Mixing:

  • Before application, two components A and B should be properly mixed under the right ratio by slowly stirring (at speed of 300 ÷ 400 rpm). 
  • The minimum mixing duration should not be less than 03 minutes and can be longer until reaching the required homogeneity. Take the mixtures for about 05 minutes then stir again before application.

Application:

  • Use a brush or short roller or pressure sprayer to apply.
  • Notes: If applying the second layer and timeout of the previous layer over time then the maximum timeout should be roughened surface by mechanical methods. Do not use mixtures over time to apply and get hardening.

Cleaning:

  • Use BestThinner SC-01 to clean equipment immediately after the execution and before the mixture’s hardening.

Safety:

  • Both components are non toxic, non flammable. However, part B is alkaline, can be allergic to skin, therefore should be prevented from direct contact to skin. 
  • Should wear comforter, gloves, protective glasses while handling the product.
  • In case of accidental eye contact, wash with fresh water and seek medical advice immediately.

Advantages

  • High strength, well bonding, crack resistance, peeling resistance.
  • Resistance to abrasion, chemical and sustainability in corrosive environments.
  • High gloss, easy to clean and wash, prevent the development of microorganisms, mold.
  • High coverage ability, easy to apply, saving material and labor.
  • Non-solvent, non-flammable, non-toxic, friendly to environment.
  • Meet the requirement of HACCP standard.

Application instruction

Hệ thống phủ:

  • Đối với bề mặt hấp thụ mạnh, bở hoặc bề mặt đã được xoa bóng bằng các chất hardener thì phải sơn lót trước bằng một lớp sơn lót BestPrimer EP601, BestPrimer EP602, BestPrimer EP603.
  • Đối với bề mặt phẳng, đặc chắc và có độ nhám trung bình thì không cần sơn lót nhưng phải sơn ít nhất 2 lớp sau khi bề mặt đã được làm sạch bằng các biện pháp thích hợp.

Điều kiện bề mặt:

  • Đối với bề mặt bê tông: Cường độ nén: ≥ 20 MPa, cường độ kéo: ≥ 1.5 MPa. Bề mặt phải bằng phẳng, đặc chắc, khô ráo (độ ẩm tối đa là 4%), các tạp chất, mảnh vỡ, bụi bẩn phải được vệ sinh đúng yêu cầu.
  • Đối với bề mặt kim loại: phải sạch rỉ sét, dầu mỡ hoặc các tạp chất khác như bụi, nước…

Trộn:

  • Trước khi thi công, hai thành phần A và B phải được trộn kỹ theo đúng tỷ lệ bằng cánhkhuấy tốc độ chậm (300 ÷ 400 rpm). 
  • Thời gian trộn tối thiểu là 3 phút nhưng có thể trộn lâu hơn cho đến khi đạt được độ đồng nhất đúng yêu cầu. Để vật liệu trong khoảng 05 phút và trộn lại trước khi thi công.

Thi công:

  • Có thể thi công bằng cọ quét, ru-lô lông ngắn hoặc vòi phun áp lực.
  • Lưu ý: Khi thi công lớp thứ hai trở đi, nếu thời gian chờ của lớp trước đã quá thời gian chờ tối đa thì phải làm nhám bề mặt bằng các biện pháp cơ học. Không sử dụng phần sơn đã hết thời gian thi công và bắt đầu đóng rắn.

Vệ sinh:

  • Dùng BestThinner SC-01 làm sạch dụng cụ ngay sau khi thi công và trước khi hỗn hợp bắt đầu đóng rắn.

An toàn:

  • Cả hai thành phần không thuộc loại nguy hiểm, dễ cháy. Tuy nhiên, thành phần B có tính kiềm có thể gây dị ứng đối với da mẫn cảm khi tiếp xúc lâu.
  • Nên mang găng tay, khẩu trang, kính bảo hộ khi sử dụng sản phẩm.
  • Trường hợp bị rơi vào mắt, mũi, miệng… phải rửa ngay bằng nước sạch nhiều lần trước khi đến cơ quan y tế nơi gần nhất để được điều trị kịp thời và đúng phương pháp. Đổ bỏ vật liệu thừa phải đúng nơi quy định của địa phương
BestCoat EP606 is an epoxy coating, non solvent, two components, protective coating for industrial flooring surface or some surfaces required load bearing, abrasion resistance, chemical resistance.