BestCoat EP604
Solvent Based Epoxy Coating, Two Components
Advantages:
Resistant to chemicals, abrasion and dust.
Antibacterial, resistant to algae/moss and mold.
No peeling or blistering.
High strength, good gloss.
High coverage capability.
Long-lasting durability.
BestCoat EP604
Technical summary
Category
Floorings
Solvent Based Epoxy Coating, Two Components
Technical documents
Product data
| Color | Yellow, blue, green, brown, gray. Custom colors can also be tinted on request with a minimum order quantity. | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Density | 1.33 ± 0.05 kg/liter at 25°C (depending on color). | ||||||||||||||||||||||||||||||
| Solids content | Minimum 65% (by weight). | ||||||||||||||||||||||||||||||
| Coverage | 0.10 ÷ 0.25 kg/m² per coat (depending on surface condition). | ||||||||||||||||||||||||||||||
| Mixing ratio | Component A : Component B = 4:1 (by weight). | ||||||||||||||||||||||||||||||
| Packaging | 30 kg/set. | ||||||||||||||||||||||||||||||
| Storage | In a dry, cool place at a temperature of 5°C ÷ 30°C, away from heat or fire sources. | ||||||||||||||||||||||||||||||
| Shelf life | 12 months from the date of manufacture (in the original sealed container, stored in a cool, dry place). | ||||||||||||||||||||||||||||||
| Application environment | Minimum +20°C (at least 5°C above the dew point). Maximum +35°C. Maximum relative humidity 80%. | ||||||||||||||||||||||||||||||
| Pot life (workable time) |
| ||||||||||||||||||||||||||||||
| Curing time |
| ||||||||||||||||||||||||||||||
| Mechanical properties | Sample after 07 days of curing at 30°C.
| ||||||||||||||||||||||||||||||
| Chemical resistance | Resistant to water, alkalis, acids, de-icing salt solutions, oils and greases, fuels and many other common chemicals. |
Applications
BestCoat EP604 is used for floors, slabs, ceilings, walls and partitions, etc. of warehouses, garages, kindergartens, cleanrooms, industrial production workshops, or places requiring high resistance to chemicals, abrasion, dust and bacteria.
Advantages
Resistant to chemicals, abrasion and dust.
Antibacterial, resistant to algae/moss and mold.
No peeling or blistering.
High strength, good gloss.
High coverage capability.
Long-lasting durability.
Application instruction
Surface preparation:
For concrete surfaces: compressive strength ≥ 20 MPa, tensile strength ≥ 1.5 MPa. The surface must be flat, dense, dry (maximum moisture 4%); impurities, debris and dust must be cleaned as required.
For metal surfaces: must be free of rust, oil, grease or other impurities such as dust and water, etc.
Coating system:
For concrete, render, natural stone and artificial stone surfaces:
01 coat of BestPrimer EP601: 0.10 – 0.25 kg/m²/coat (depending on surface condition).
02 coats of BestCoat EP604: 0.10 – 0.25 kg/m²/coat (depending on surface condition).
For metal surfaces:
02 coats of BestCoat EP604: 0.10 – 0.25 kg/m²/coat.
Mixing:
Add component B into component A at the specified ratio. Use an electric mixer or a dedicated mixing machine (300 to 500 rpm) to mix the material for about 3 minutes or longer until the mixture is homogeneous. Let the mixture stand for about 10 ÷ 15 minutes, then stir again before application.
Application:
Can be applied with a brush, short-nap roller or pressure spray gun.
Notes:
When subdividing into smaller portions, stir component A well before weighing.
Do not use paint that has exceeded its workable time and has started to cure.
Cleaning:
Use BestThinner SC-01 to clean tools immediately after application and before the mixture starts to cure.
Safety guidance:
Both components are hazardous and flammable; keep away from heat sources, electric sparks or open flames during application or storage.
The product may cause irritation to sensitive skin on prolonged contact. Wear gloves, a mask and safety goggles when applying the product.
If splashed into the eyes, nose or mouth, rinse immediately with plenty of clean water several times before going to the nearest medical facility for timely and proper treatment.
Dispose of excess product at locations designated by local regulations.